Company Overview
Products
Programs
Newsflash
Sales Network
Technical Data

Photometry
Section Descriptions
Wraps •• Industrials •• Extreme •• Striplights
BR BR Stretto VHC HC P2 P4SC P4 P4D EMX NP 45
PW FW LSL VC HH/HV

Open Office with Partitions
Tenant's Choice vs. 3-L Parabolic - 8x8 O.C.

Although max/min ratios are about the same in this comparison, Tenant's Choice fits perfectly within the desired 20-50 footcandle range while consuming 50% less power.

Description: TC24-232G-MA36-EB8
2x4 2-Lamp Parabolic with 3x6 Cell, Matte Aluminum Louver T8 Electronic Ballast
Quantity: 16
Lamps: (2) F32/T8, 2850 Lumens
LLF: 0.75
Test#: 11909

Statistics

Min Max Ave Ave/Min Max/Min
19 55 37 1.95 2.90

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
928 .8 37
   
Description: P424-332G-LD36-X-3EB8
2x4 3-Lamp Parabolic with 3x6 Cell, Semi-Specular Louver (1) 3-L T8 Electronic Ballast
Quantity: 16
Lamps: (3) F32/T8, 2850 Lumens
LLF: 0.77
Test#: 11063

Statistics

Min Max Ave Ave/Min Max/Min
35 86 63 1.80 2.46

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
1392 1.2 63
 
 