Company Overview
Products
Programs
Newsflash
Sales Network
Technical Data

Photometry
Section Descriptions
Wraps •• Industrials •• Extreme •• Striplights
BR BR Stretto VHC HC P2 P4SC P4 P4D EMX NP 45
PW FW LSL VC HH/HV

Open Office with Partitions
Tenant's Choice vs. 3-L Parabolic - 8x10 O.C.

In the examples below Tenant's Choice outperforms the traditional 3-L parabolic with low power consumtion and superior max/min ratios.

Description: TC24-232G-MA36-EB8
2x4 2-Lamp Parabolic with 3x6 Cell, Matte Aluminum Louver T8 Electronic Ballast
Quantity: 12
Lamps: (2) F32/T8, 2850 Lumens
LLF: 0.75
Test#: 11909

Statistics

Min Max Ave Ave/Min Max/Min
12 41 28 2.33 3.42

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
696 .6 28
   
Description: P424-332G-LD36-X-3EB8
2x4 3-Lamp Parabolic with 3x6 Cell, Semi-Specular Louver (1) 3-L T8 Electronic Ballast
Quantity: 12
Lamps: (3) F32/T8, 2850 Lumens
LLF: 0.77
Test#: 11063

Statistics

Min Max Ave Ave/Min Max/Min
11 68 46 4.18 6.18

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
1044 .9 46
 
 