Open
Office with Partitions
Tenant's Choice 8x8 O.C. vs. 3-L Parabolic - 8x12 O.C.
In
this comparison, note the high max/min value of the traditional
parabolic. On 8'x12' centers the 3-L fixture may leave work areas
with inadequate and uneven illumination.
|
 |
| Description: |
TC24-232G-MA36-EB8
2x4 2-Lamp Parabolic with 3x6 Cell, Matte Aluminum Louver T8
Electronic Ballast |
| Quantity: |
16 |
| Lamps: |
(2)
F32/T8, 2850 Lumens |
| LLF: |
0.75 |
| Test#: |
11909 |
Statistics |
| Min |
Max |
Ave |
Ave/Min |
Max/Min |
| 19 |
55 |
37 |
1.95 |
2.89 |
Energy
Consumption |
Area
(Sq. Ft.) |
Total
Watts |
Watts
Per
Sq. Ft. |
Average
Footcandles |
32'x36'
(1152) |
928 |
.8 |
37 |
|
| |
|
|
| Description: |
P424-332G-LD36-X-3EB8
2x4 3-Lamp Parabolic with 3x6 Cell, Semi-Specular Louver (1)
3-L T8 Electronic Ballast |
| Quantity: |
12 |
| Lamps: |
(3)
F32/T8, 2850 Lumens |
| LLF: |
0.77 |
| Test#: |
11063 |
Statistics |
| Min |
Max |
Ave |
Ave/Min |
Max/Min |
| 9 |
57 |
41 |
4.56 |
6.33 |
Energy
Consumption |
Area
(Sq. Ft.) |
Total
Watts |
Watts
Per
Sq. Ft. |
Average
Footcandles |
32'x36'
(1152) |
1044 |
.9 |
41 |
|