Company Overview
Products
Programs
Newsflash
Sales Network
Technical Data

Photometry
Section Descriptions
Wraps •• Industrials •• Extreme •• Striplights
BR BR Stretto VHC HC P2 P4SC P4 P4D EMX NP 45
PW FW LSL VC HH/HV

Open Office
Tenant's Choice vs. 3-L Parabolic - 8x10 O.C.

In the comparison below, Tenant's Choice provides the perfect amount of light for today's electronic offices at only .6 watts-per-square-foot.

Description: TC24-232G-MA36-EB8
2x4 2-Lamp Parabolic with 3x6 Cell, Matte Aluminum Louver T8 Electronic Ballast
Quantity: 12
Lamps: (2) F32/T8, 2850 Lumens
LLF: 0.75
Test#: 11909

Statistics

Min Max Ave Ave/Min Max/Min
30 52 38 1.27 1.73

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
696 .6 38
   
Description: P424-332G-LD36-X-3EB8
2x4 3-Lamp Parabolic with 3x6 Cell, Semi-Specular Louver (1) 3-L T8 Electronic Ballast
Quantity: 12
Lamps: (3) F32/T8, 2850 Lumens
LLF: 0.77
Test#: 11063

Statistics

Min Max Ave Ave/Min Max/Min
52 71 62 1.19 1.37

Energy Consumption

Area
(Sq. Ft.)
Total Watts Watts Per
Sq. Ft.
Average
Footcandles
32'x36'
(1152)
1044 .9 62
 
 

Additional Comparisons:
Open Office, 8'x8' O.C.
Open Office, 8'x10' O.C.
Open Office With Partitions, 8'x8' O.C. vs. 8'x12' O.C.
Open Office With Partitions, 8'x10' O.C.
Open Office With Partitions, 8'x8' O.C.

 

back


Terms of Use
© Columbia Lighting 2008