Open
Office
Tenant's Choice vs. 3-L Parabolic - 8x8 O.C.
The
comparison below shows how a traditional parabolic overlights an
open office space while consuming 50% more energy than the Tenant's
Choice.
|
|
| Description: |
TC24-232G-MA36-EB8
2x4 2-Lamp Parabolic with 3x6 Cell, Matte Aluminum Louver T8
Electronic Ballast |
| Quantity: |
16 |
| Lamps: |
(2)
F32/T8, 2850 Lumens |
| LLF: |
0.75 |
| Test#: |
11909 |
Statistics
|
| Min |
Max |
Ave |
Ave/Min |
Max/Min |
| 39 |
62 |
48 |
1.23 |
1.59 |
Energy
Consumption
|
Area
(Sq. Ft.) |
Total
Watts |
Watts
Per
Sq. Ft. |
Average
Footcandles |
32'x36'
(1152) |
928 |
.8 |
48 |
|
| |
|
|
| Description: |
P424-332G-LD36-X-3EB8
2x4 3-Lamp Parabolic with 3x6 Cell, Semi-Specular Louver (1)
3-L T8 Electronic Ballast |
| Quantity: |
16 |
| Lamps: |
(3)
F32/T8, 2850 Lumens |
| LLF: |
0.77 |
| Test#: |
11063 |
Statistics
|
| Min |
Max |
Ave |
Ave/Min |
Max/Min |
| 64 |
92 |
80 |
1.25 |
1.44 |
Energy
Consumption
|
Area
(Sq. Ft.) |
Total
Watts |
Watts
Per
Sq. Ft. |
Average
Footcandles |
32'x36'
(1152) |
1392 |
1.2 |
80 |
|